The cooking compartment is still dirty after running the cleaning programme. Several causes can lead to an unsatisfactory result.
| Possible Cause | How to Fix |
|---|---|
| Locking cap still on cleaning cartridge | Remove spent cartridge (do not reuse). Insert new cartridge with cap removed. Re-run programme. |
| Drain filter was missing | Ensure drain filter remains inserted in cooking compartment floor during cleaning |
| Power failure during cleaning (>3 min) | Programme ended early. Re-run cleaning programme. |
| Heavily baked-on dirt | Run the cleaning programme a second time for stubborn residue |
Use only genuine Gaggenau cleaning cartridges (order number CLS10040, set of 4).
As an affiliate, we may earn from qualifying purchases. This doesn't affect our recommendations.
Find top-rated Gaggenau BS47/BS48.112 repair technicians in your area. Licensed, insured, and reviewed by homeowners.
We may earn a referral fee when you hire through our partner links.